Murata has introduced two MEMS sensors that use BCG (BallistoCardioGraphic) techniques to detect and measure a patient’s heart rate without the need for any wires or connections. Designed for continuous patient monitoring at elderly care centres, hospitals or in the home, the SCA11H sensor node and SCA10H sensor module can be used in applications such as bed occupancy monitoring and sleep quality analysis.

With ballistocardiology, an extremely sensitive MEMS sensor is used to detect the recoil effect of the heart pumping blood around the body. When lying on a bed the entire bed will start to vibrate due to this movement. The MEMS accelerometer captures this signal which is then passed to an MCU running a special algorithm. This allows the MCU to extract heart rate and other vital signs information from the signal.

The SCA10H is a PCB module comprising the sensor and MCU that is designed for medical device and equipment manufacturers to incorporate into their own products, or even into a hospital bed. This module measures just 28x26x7mm and requires a supply voltage in the range 8 to 10VDC. It consumes 8mA and can detect pulses in the range of 40-120bpm.

The SCA11H sensor node is a complete BCG-based product that comprises the sensor, MCU and a WiFi transceiver. This is all housed in an IP55-rated waterproof enclosure that measures 84x41x18mm. This is suitable for software solution providers and system integrators that wish to focus on service creation rather than become involved in designing electronic systems. The WiFi transceiver is capable of operating in either a local mode or a cloud mode. The local mode is used for presenting and processing data in a local network using a mobile application while the cloud mode enables connection to a cloud service architecture. The sensor node also supports over-the-air firmware upgrades.

A software development tool kit will be available for the SCA11H WiFi sensor node to aid developers integrate it into their own applications.

Both sensors can output a range of vital signs including heart rate (bpm), respiration rate (rpm), heart rate variability, relative stroke volume together with bed occupancy / movement sensing, but are not qualified or approved as such for medical use. OEMs manufacturing systems are responsible for potential medical approvals required in their specific use.

The SCA11H and SCA10H will be showcased at booth 8BK17 during MEDICA/COMPAMED in Düsseldorf, 16th to 19th November.