IIoT-enabled M-Bus level converter with extended functionality
STV Electronic has completely redesigned its M-Bus level converter family, optimising it for use in smart metering and IIoT applications. Newly added features include level and protocol converter functions from M-Bus to USB, support of IPv4/IPv6 and real-time MQTT messaging with M-Bus to Ethernet, as well as an integrated web server for parametrisation and monitoring of standard M-Bus loads.
Previous versions offering only RS-232 or RS-485 interfaces have also been updated and are now available with additional optional Ethernet. The IP-based parametrisation interface greatly facilitates the implementation of these Ethernet-based MPW-IP level converters as no special software is required.
Further benefits include more options to monitor M-Bus connected meters and adaptive sensors. It also becomes easier to parametrise and monitor actuators that control power supply and consumption, such as switches and power controllers or pumps and valves. The new M-Bus level converters are used in electricity, gas, water and district heating networks.
Customers of the new M-Bus level converter family include project developers, system integrators and the electrical trade; end consumers such as industrial companies with DIN EN ISO 50001-compliant energy management systems, private property operators and home owners; as well as public-sector clients such as municipal housing associations, universities and hospitals.
Energy supply companies can also leverage the new converters as an interface between Smart Meter Gateways (SMGW) and local M-Bus devices since the level converters are protocol-agnostic. They therefore also meet the requirements of end-to-end encryption as enabled, for instance, by Open Metering System (OMS) compatible smart meters and sub meters.
"The new M-Bus level converters give our customers an entirely new implementation and user experience with significantly more comfortable control along with the usual fail-safe and reliable operation," explained Markus Hühn, Managing Director of STV Electronic.
In the past, people installed M-Bus level converters either hoping that the standard M-Bus loads would match the level converter, or spending a lot of time measuring M-Bus loads. Today, proper operation - including maximum permissible current - can be checked in real time via the level converter's web server. In the past, M-Bus devices were also parametrised locally via the serial interface of the level converter. This required the installation of special software on the service computer.
Today, it is possible to parametrise and monitor proper operation, including maximum permissible current over time, from anywhere in the world via the integrated web server - all of this password protected, of course. This gives users full control at all times over their energy management and resource consumption and allows them to operate their facilities and buildings efficiently, even remotely.
The new M-Bus level converters of the STV Electronic MPW and MPW-IP series offer level and protocol converter functions from M-Bus to RS232, RS485, USB or Ethernet interfaces, as well as from M-Bus to Ethernet in combination with RS232 or RS485. All Ethernet variants support IPv4/IPv6 and real-time MQTT messaging as well as an integrated web server for parametrisation and monitoring of standard M-Bus loads.
The new MPW level converters, which for legacy applications still support only RS232/485, require no additional parametrisation. Thanks to their new multi-coloured LEDs, send data can now be displayed in addition to receive data. With wiring errors and M-Bus overloads being flagged, the RS232/485 variants are also extremely easy to service.
The new level converters with galvanic isolated interfaces are available in finely graded versions for two, six, 16, 32, 64 and 128 standard loads of 1.5mA each. They support M-Bus transmission rates from 300 to 38,400 Baud and are therefore also suitable for fast M-Bus devices. Thanks to a high M-Bus voltage of 37 to 40V, the converters can also be used for the safe operation of large M-Bus networks with long cables. Power is supplied by a 24 Volt AC/DC unit, and the highly compact level converters are mounted on TS35 rails or using screw lugs.
The new level converters from STV Electronic are available as individual components or, if required, in combination with the RaspberryPi based 'Smart Manager 4.0' DIN rail computer, which can also be used to provide extensive edge logic for energy data acquisition and control as an additional option.