Production

LUVIR technology speeds up PCB solder mask production

6th August 2020
Lanna Deamer
0

Provider of Laser Direct Imaging (LDI) systems for PCB manufacturing and adjacent markets, Limata has announced the availability of its proprietary and field-proven LUVIR Technology on all X-series model types. This unique LDI technology significantly increases the speed of Solder Mask (SM) direct imaging at lower Total Cost of Ownership (TCO).

Innovation reduces required UV-power and increases imaging speed

Direct Imaging (DI) of solder masks in PCB manufacturing, which is essential to comply with the latest PCB design requirements in the area of registration and accuracy, has always been a challenging task.

Since solder mask inks require significantly higher doses of Ultra-Violet (UV) energy than dry-film, the imaging processing times of multi-wavelength DI solutions (solely relying on UV-light sources) are either too slow for high volume requirements or fail to deliver the required SM imaging output capacity at a reasonable investment for the manufacturer.

To tackle this challenge, Limata has developed a completely new approach for solder mask exposure, that utilises both, UV- and infrared (IR-) lasers. This combined laser approach shortens imaging cycle times and increases throughput (prints or panels per hour) further delivering ionic contamination (‘bleeding’) values on all conventional ink types.

"With LUVIR, we are able to deliver the same imaging results at lower UV-laser energy levels of just 100 to 250mJ/cm2 compared with 400 to 1,000mJ/cm2 required on LED/DMD systems - with no compromises on surface quality, resolution or accuracy," said Matthias Nagel, CTO of Limata.

"Using IR enables us to downsize the UV-laser capacity in our systems, which supports lower equipment costs, ultimately delivering the best price/performance value of any DI solder mask system currently available in the market.”

Outstanding imaging results on all conventional ink types

Higher imaging efficiency and throughput levels with LUVIR are particularly achieved on all conventional solder mask ink types and colors (green, blue and black) as well as on legend inks (white), further eliminating the need for PCB manufacturers to transition from conventional standard ink material to more expensive DI inks, a change which normally requires lengthy and costly re-certifications of solder mask processes by end-customers or PCB designers.

In addition, LUVIR fully supports the digital imaging of PCB structures at coating thicknesses in the 4 mil (100µm) to 6 mil (150µm) range without significant undercut. This is a direct imaging task that cannot be processed by multi-wavelength DMD/LED systems at reasonable speed levels or yields.

Lower Cost-per-Print and Total Costs of Ownership for PCB manufacturers

PCB production data from the field have proven a significant imaging and throughput advantage with LUVIR on all conventional solder mask inks at up to 40% lower costs per print compared to DI system peers.

The use of long-lifetime components for its UV/IR imaging module complemented by an in-house developed sensor array for the automatic remote calibration of lasers significantly reduces maintenance requirements and after-sales costs by further eliminating the need for manufacturers to enter into expensive long term service agreements over the equipment lifecycle.

LIMATA’s X2000-series platform, powered by LUVIR in a four UV/IR imaging head configuration, supports high volume PCB capacity requirements. The availability of LUVIR on a more compact system platform (X1000) lowers the entry barriers for quick-turn-around manufacturers considering transitioning from mask/film and investing in a digital system solution for solder mask direct imaging.

LIMATA was recently acknowledged for its LUVIR innovation with the Productronica Innovation Award 2019 in the PCB & EMS Cluster. The technology is available on all LIMATA X-series system models featuring a range of options addressing individual PCB customer needs in different markets and regions.

All X-Series systems also support the direct-imaging of dry-film (photoresist) down to a resolution of 1 mil (25µm) line and space.

Featured products

Product Spotlight

Upcoming Events

View all events
Newsletter
Latest global electronics news
© Copyright 2024 Electronic Specifier